Quick Answer:
Minutes, not hours. Set sensor orientation, servo-center, and set the guide point—no manual calibration needed when materials change.
Once the guide is mounted, commissioning is a short menu sequence on the controller: set sensor orientation, check jog direction, servo-center, set the guide point, and switch to Automatic. This is particularly valuable for converters running short production runs with frequent changeovers—there is no need to move sensors or recalibrate when switching materials or web widths.