Quick Start GuidesRetrofit an Existing Web Guide

Start here Select Your Sensor

Pick your ODC Family model to unlock datasheets, 3D models, support files, and your exact ordering list:

Not sure which size? Pick the sensor wide enough for your max expected wander + 10% margin. View all ODC Family models

Select your sensor model above to unlock datasheets, 3D models, support files, and your exact ordering list for this guide.

What You'll Achieve

After completing this guide, your existing guide runs on Roll-2-Roll control with the slave web following the master web's side-to-side position — the new actuator keeps the two layers aligned.

Estimated time: ~30–60 minutes

What You Need

Master-Slave Guiding — SCU5

Prerequisites

1 Install the Web Guide

Install the Roll-2-Roll sensor, controller, and actuator onto your existing web-guide structure — reuse the mechanical carriage, replace the controls.

DANGER
Match the actuator mount to your existing structure Identify whether your existing carriage uses a fixed (-RF) or floating (-TG) mount before ordering or installing the actuator. Fixed structures take an LHS-RF actuator; floating structures take an LHS-TG, BLA, or RLA sized to the load. Installing a fixed-mount actuator on a floating structure — or a floating-mount actuator on a fixed structure — will damage the actuator.

Confirm the Existing Web-Guide Frame

  • Confirm the frame is still solidly bolted to the machine through its base-plate holes, with no loose or missing fasteners.
  • Confirm the web travels in the direction of the arrows on the frame. The guide corrects in one direction only, so a frame turned around during its service life fights the web instead of steering it.
  • Confirm the frame is level — rollers parallel to the machine idlers and square to web travel, with no tilt to either side. Check it with a machine square, a tram rod, or by measuring from each entry and exit roller to the guide roller.
  • Rock the moving carriage by hand and feel for play in the guide bearings. Slop or a notchy, catching feel means worn bearings — plan to clean or replace them before you fit the new actuator.

Reference Documents

2 Install the Sensor

Install the Sensors — Master-Slave Guiding

  • Master-slave guiding uses two ODC infrared sensors on two separate web paths: a master sensor on the master (reference) web and a slave sensor on the web this retrofitted guide steers.
  • Line up the master and slave sensors at the same point across the machine, relative to the machine centerline.
  • Make the web-path length from the master sensor to the lamination point equal to the path length from the slave sensor to the lamination point — this timing has to match.
  • Mount the slave sensor in the exit span after its guide roller, as close to the roller as your machine allows, and mount both sensors the same way round.

3 Wire the System

4 Configure & Verify

Power up the controller and commission the retrofitted guide, one checked step at a time.

Master-Slave Guiding — Power Up and Commission

Commission master-slave guiding on your retrofitted guide — set up the slave guide first, then bring in the master so the slave web follows it.

  1. Power on the controller. If it wakes in Automatic, switch to Manual — it resumes whatever mode it was last in, and every step below runs from Manual.
  2. Set both sensors to edge sensing. The master sensor reads the master (reference) web; the slave sensor reads the web this guide steers.
  3. Disable the master sensor for now — you'll commission the slave guide on its own first.
  4. Set the slave sensor's orientation to Left or Right to match its edge, on the Power User → Sensor screen, and check it on the Web Position Indicator — you should see a dark region on the matching side. If it reads all dark or all light, fix the working distance or orientation before continuing.
  5. Check the jog direction. Tap Jog Left, then Jog Right, and watch the guide. It should move the way each button says. If it moves the opposite way, reverse Motor Polarity under Power User → Actuator → Motor Polarity, then jog again to confirm.
  6. Servo-center the actuator. Tap Servo Center and let the guide travel to its home position (half its stroke each way). If it heads away from home instead of toward it, reverse Servo Center Polarity under Power User → Actuator → Servo Center Polarity, then servo-center again. If it hits a mechanical stop before finishing, re-check the servo-center sensor position from the pre-power checks.
  7. Set the guide point for the slave web, then switch to Automatic and confirm the slave web corrects the right way. If it steers away from the guide point, reverse Error Polarity under Power User → Controller, then watch it correct again. Get steady slave guiding before adding the master.
  8. Enable the master sensor and set its orientation to match its edge the same way, on the Power User → Sensor screen, then check it on the Web Position Indicator. Turn on the master/slave function.
  9. Confirm which sensor is master and which is slave — the master supplies the guide-point offset, the slave is the edge the actuator follows.
  10. Check the master/slave polarity. Shift the master web off its sensor center and watch the slave web move the same way. If the slave web moves the opposite way, flip the master/slave polarity, then re-check.
  11. Prove the safety hold. Lock on Lost Edge watches the slave web — pull the slave web out of its sensor's view and confirm the guide holds its last position. When the slave web tracks the master and the hold works, your retrofitted web guide is commissioned.

5 PLC Integration

The controller accepts remote commands two ways — over Industrial Ethernet, or through the DIO option's discrete 24 V dry-contact inputs. Either lets a PLC command guide mode and position without touching the controller screen.

  • Industrial Ethernet (C(x) models) — send auto-mode on/off, jog, servo-center, and guide-point commands over EtherNet/IP, PROFINET, or EtherCAT.
  • DIO option — hard-wired 24 V NPN dry-contact inputs for remote on/off and mode switching, no Ethernet required, wired straight from PLC digital outputs or relay contacts.
  • The two can run together — Ethernet for data and fine control, DIO for hard-wired interlocks.
  • Lock on Lost Edge inhibits actuator motion when the guided edge leaves the sensor's view; Loss of Contrast Inhibit does the same when a taught line or contrast feature is lost.

📄 The register map, EDS file (EtherNet/IP), and Add-on Instruction (AOI) for Studio 5000 are in the Your Products section above — grouped on the product card with everything else you need to download.