Skip to main content
Quick Start GuidesIntermediate Web Guide

Start here Select Your Sensor

Pick your ODC Family model to unlock datasheets, 3D models, support files, and your exact ordering list:

Not sure which size? Pick the sensor wide enough for your max expected wander + 10% margin. View all ODC Family models

Select your sensor model above to unlock datasheets, 3D models, support files, and your exact ordering list for this guide.

What You'll Achieve

After completing this guide, your web tracks a contrast boundary — a coating edge, color change, or stripe — and the guide follows it.

Estimated time: ~30–60 minutes

What You Need

Contrast Guiding — SCU6x

Prerequisites

1 Install the Web Guide

Install the Roll-2-Roll® Web Guide in two stages: first mount and align the web-guide frame on your machine, then mount the sensor for your guiding mode.

Install and Align the Web Guide Frame

  • Bolt the frame to the machine through its base-plate holes.
  • Mount it so the web travels in the direction of the arrows on the frame — the guide corrects in one direction only, so a backwards frame fights the web instead of steering it.
  • Level the frame: set its rollers parallel to the machine idlers and square to web travel, with no tilt to either side. Check it with a machine square, a tram rod, or by measuring from each entry and exit roller to the web-guide roller — whichever you have.

Reference Documents

2 Install the Sensor

Install the Sensor — Contrast Guiding

  • Contrast guiding uses a single ODC sensor over the contrast boundary (a coating edge, color change, or stripe), and needs a backup roller (any roller or dead bar) directly under the sensor to hold the working distance steady — a plane change reads as a contrast change. Keep the wrap as small as possible.
  • Any roller or dead bar works as the backup roller. Keep its wrap as small as possible so it doesn't change how the web moves in the exit span.

3 Wire the System

4 Configure & Verify

Power up the controller and commission the guide, one checked step at a time.

Contrast Guiding — Power Up and Commission

Commission single-sensor contrast guiding — teach the boundary, prove the motion, then track it in automatic.

  1. Power on the controller. If it wakes in Automatic, switch to Manual — every step below runs from Manual.
  2. Set the sensor to contrast sensing.
  3. Teach the boundary. On the Operator → Sensor screen, enter teaching mode, pick the contrast mode from the on-screen icons, and use the left/right arrows to land on your boundary (a coating edge, color change, or stripe) in the live image. Save with the gear button — it turns red and a green box locks around the boundary. Until a valid feature is taught, the controller stays interlocked and won't enter Automatic.
  4. Check the jog direction. Tap Jog Left, then Jog Right, and watch the guide. It should move the way each button says. If it moves the opposite way, reverse Motor Polarity under Power User → Actuator → Motor Polarity, then jog again to confirm.
  5. Servo-center the actuator. Tap Servo Center and let the guide travel to its home position (half its stroke each way). If it heads away from home, reverse Servo Center Polarity under Power User → Actuator → Servo Center Polarity, then servo-center again.
  6. Set the guide point. Tap Reset Guide Point to lock the target onto the boundary's current position. (To offset it, drag the guide-point bar and press Accept.)
  7. Switch to Automatic. The guide now tracks the taught boundary. If it won't enter Automatic, the boundary isn't taught or isn't in view — re-teach at step 3.
  8. Check the correction direction. Nudge the web so the boundary moves off target. The guide should bring it back. If it drives the boundary further off, reverse Error Polarity under Power User → Controller, then watch it correct again.
  9. Fine-tune the position. Still in Automatic, tap Jog Right (+) or Jog Left (−) to nudge the tracked boundary to the exact spot — about 0.25 mm (0.01 in) per tap.
  10. Prove the safety hold. Pull the boundary out of the sensor's view. The guide should hold its last position (it won't recenter) until the boundary returns. When it holds, your contrast guide is commissioned.

5 PLC Integration

Web guiding controllers support remote command via two routes: Industrial Ethernet PLC remote control, and the DIO option (discrete dry-contact inputs). Both allow a PLC or supervisory system to command guide mode and position without manual touchscreen interaction.

  • Route 1 — PLC remote control (C(x) models): send auto mode on/off, jog, servo center, and guide-point commands over Industrial Ethernet (EtherNet/IP, PROFINET, EtherCAT)
  • Route 2 — DIO option: discrete dry-contact 24 V NPN inputs for hard-wired remote on/off and mode switching — no Industrial Ethernet required; wired directly from PLC digital outputs or relay contacts
  • Both routes can coexist — Ethernet for data and fine control, DIO for hard-wired safety/interlock inputs
  • Lock on Lost Edge: when the web edge exits the sensor field of view during edge guiding, actuator motion is inhibited — prevents runaway
  • Loss of Contrast Inhibit: for line/contrast guiding, actuator motion is inhibited if contrast is lost until the target feature is re-acquired

📄 The register map, EDS file (EtherNet/IP), and Add-on Instruction (AOI) for Studio 5000 are in the Your Products section above — grouped on the product card with everything else you need to download.

+ Go Further

Related Quick Start Guides

Learn More

Need Help?

Email: experts@r2r.tech
Phone: +1-888-290-3215