Your Sensor
Select your ODC Family model to unlock datasheets, drawings, and 3D models:
Not sure which size? Pick the sensor wide enough for your max expected wander + 10% margin. View all ODC Family models
Your Products
What You'll Need to Order
| Qty | Item | SKU | Connection |
|---|---|---|---|
| 1 | Quick Disconnect Sensor Cable - 3m (10 ft) | U2-01975 |
sensor.connector → controller.S1 |
| 1 | 24 V DC Input Power Cable, Length 5 m | 21218-5m |
power.output → controller.P1 |
| 1 | M12 to RJ45S, Shielded Cable - 9.8ft/3m | 21222-3m |
controller.Port3 → plc.input |
| 1 | Quick Disconnect Sensor Cable - 3m (10 ft) | U2-01975 |
sensor2.connector → controller.S2 |
Select cable length based on your installation distance
BOM generated for sensor model: odc-288
BOM generated for controller: scu5
What You'll Achieve
After completing this guide, wired to your SCU5 C(x)D controller with width data available over Industrial Ethernet for your PLC.
Estimated time: ~2–3 hours
What You Need
Prerequisites
SCU5 Output Options
The "+" is the analog-output option — it adds a live analog signal of the width value on top of the model's base capability, so a single controller can drive more than one output at once.
| Model | Outputs |
|---|---|
| SCU5 C(x)D | Industrial Ethernet width data (overall width, left/right edge, centerline — loggable) |
| SCU5 C(x)D+ | Industrial Ethernet width data, plus an analog output of the width value |
Install the Sensor
Edge-based web width measurement always uses free span mounting (web unsupported between rollers). Install the sensor so that the length of the sensor is parallel to the cross-machine direction (the width direction of the web).
Dual Sensor Setup
- Position the left sensor to see the left edge, right sensor to see the right edge
- Critical: mount both with the same camera (physical) orientation, but set their electronic orientation oppositely — the left sensor tracks the left edge, the right sensor the right edge
- Each sensor needs margin for the full range of web widths (min to max) plus wander
- Sensors do not need to be the same size — select each based on wander range at its edge
Reference Documents
Wire the System
Same sensor wiring as analog, plus Ethernet cable.
- Sensor: Connect Quick Disconnect Sensor Cable (U2-01975) from ODC Family sensor to SCU5 port S1 (and S2 for dual)
- Power: Connect 24 V DC Input Power Cable (21218-5m) to SCU5 port P1
- Ethernet: Connect M12 to RJ45S, Shielded Cable (21222-3m) from SCU5 Port 3 to PLC or network switch
Configure & Verify
Web width measurement computes the distance between the detected left and right edges. The controller computes the width internally and provides the value directly.
Dual Sensor Width
Two sensors — one per edge — with the controller computing total width including the distance between sensors. Use when the web is wider than any single sensor. Not available for 1DC.
- Set each sensor's electronic orientation first — left sensor → left edge, right sensor → right edge — then perform single-sensor configuration for each
- Teach offset: place a known-width sample so both sensors see their edges
- Enter the known width value and press the Teach Offset button
- The controller computes the distance between sensors and stores it
- Optionally perform teach correction after teach offset for better repeatability
Common Configuration Mistakes
- Not re-teaching correction after product change — measurements drift with a different material
- Forgetting teach offset — width will be wildly incorrect (missing distance between sensors)
PLC Integration
The controller provides computed web width (with offset and correction applied) in dedicated registers. No PLC-side computation needed unless you prefer raw measurements.
- Width is provided as a 16-bit register value with offset and correction applied
- Raw edge positions (left and right) also available for PLC-side computation
- For PLC-based tolerance monitoring: read width register, compare against nominal ± tolerance
- Rockwell AOI handles pixel-to-mm conversion and bit unpacking automatically
📄 The register map, EDS file (EtherNet/IP), and Add-on Instruction (AOI) for Studio 5000 are in the Your Products section above — grouped on the product card with everything else you need to download.
Go Further
Related Quick Start Guides
- Multiple Web Width Measurement — Measure multiple strips or webs simultaneously (SCU6x only)
- Position Measurement — Measure edge, centerline, or contrast/line position
- Splice Detection — Add splice detection alongside width measurement
Learn More
Need Help?
Email: experts@r2r.tech