1110 S Innovation Way Dr Stillwater, OK 74074 Opto-Isolated Output E: sales@r2r.tech W: https://r2r.tech P/F: +1-888-290-3215

For some applications a digital output can be provided based on the application. Two opto-isolated outputs are available from the SCU5 controller. These outputs are available on a 4-pin M12 female pin connector. A standard M12 4-pin A coded male connector or a pre-wired M12 cable can be used for the connection. The pin functions for the connector are shown in the table below.

Pin Assignment: Pin Function Pin Function Pin Function Pin Function

1-BR/RD VDD 2-WH OUT2 3-BL/GN GND 4-BK OUT1 The outputs can be used as NPN normally closed output by providing a VDD (5 - 24 VDC) and GND from a PLC and the signal through the two outputs OUT1 and OUT2. A typical circuit for the output is shown below:

When the respective output signal is enabled then that signal would go low. And normally the signal would be high if wired as shown in the schematic on the left. Note that the outputs are normally closed. If wiring a relay, wire to the NC side of the circuit so that the appropriate output from the relay is provided to the device.

All Right Reserved. Copyright © 2021 Roll-2-Roll Technologies LLC. Content subject to change without notice. Page 1 of 2

1110 S Innovation Way Dr Stillwater, OK 74074 Opto-Isolated Output E: sales@r2r.tech W: https://r2r.tech P/F: +1-888-290-3215

Connecting the output to PLC with PNP inputs can be done using a replay as shown below: