1110 S Innovation Way Dr Standard Operating Procedure Stillwater, OK 74074 Edge Guiding Application E: sales@r2r.tech W: https://r2r.tech P/F: +1-888-290-3215
During a product changeover or after a width change the following settings can be followed to startup the web guide. Step 1: If the web guide is in Automatic mode switch it to manual mode as shown below.
Step 2: Servo center the web guide.
Step 3: If needed position/thread the web at the desired location on the rollers. Step 4: If needed, position the sensor so that web is approximately in the middle of the sensing window.
Step 5: On the SCU5 operator interface ensure that the web edge is in the middle and reset the guide point if needed.
Step 6: Press the Automatic/manual button to put the web guide in Automatic Mode.
Step 7: If needed use the fine guide point adjustment to fine tune the desired guided web location. Note: This procedure is for the right sensor mode but the same procedure is applicable for left sensor mode as well.